Aurinex Building Systems / Technical manual

Product systems, section logic and project checks.

Use this manual to shortlist a system, read the published limits and prepare a quote-ready product brief. The final glass, hardware, performance route and compliance package are confirmed against the project drawing and destination market.

Back to product catalogue
Document status Working technical reference. Published values are a first selection; they are not a substitute for approved shop drawings, structural review or local code confirmation.
DocumentABS-TECH-001
RevisionR01 / 15 OCT 2026
OwnerAurinex Building Systems
StatusFor design coordination

01

How to read a product row

Every row answers a different project question. Start with the opening type, then check the profile, performance route, hardware and size band as one package.

01

Opening

Fixed, casement, lift-and-slide, folding, facade bay or outdoor system.

02

Frame

Depth, wall thickness, thermal break, mullion or transom relationship.

03

Performance

Uw, air, water, wind and acoustic values depend on the complete tested or engineered assembly.

04

Built size

The published manufacturing band is a starting point. Oversize, exposure and repetition require review.

02 / Families

System classification and selection path

The drawings identify each system family. Final construction is controlled by the approved section, project drawing and technical submittal.

H98S window renderH98S window section
WINDOWS / H98S / FZ75

Punched openings

Thermal-break casement families for repeated room openings, with inward tilt-and-turn and screen options.

Read family data
F150TS lift-and-slide door renderF150TS lift-and-slide door section
DOORS / F130T / F150TS

Large openings

Lift-and-slide and folding systems selected by opening width, leaf load, track, drainage and exposure.

Read family data
MQ65 stick facade renderMQ65 stick facade section
FACADE / MQ65

Repeated bays

A stick facade grid where mullion, transom, insert, span and site glazing are coordinated as one elevation.

Read family data
YSP147 louver pergola renderYSP147 louver pergola section
OUTDOOR / YSP147

Shade and weather

A louver pergola family with published module sizes and manual or electric drive options.

Read family data

02A / Dimensional drawings

Read the elevation, plan and section together.

These drawings turn the catalogue row into a coordination reference. They show the published dimensions and relationships; they are not factory cutting drawings or structural calculations.

F150TS elevation plan and section dimensional drawing
F150TSLarge opening / 150 mm frame / 300 or 500 kg sash route
H98S elevation plan and section dimensional drawing
H98SWindow / 98 mm frame / 450-900 x 600-2400 mm
MQ65 facade elevation plan and section dimensional drawing
MQ65Facade bay / mullion 65 x 192 / transom 65 x 128
YSP147 pergola plan elevation and louver detail
YSP147Outdoor / 6063 aluminium / published module family

02B / Product datasheets

Product technical datasheets

Each datasheet consolidates the 3D view, section reference, published dimensions, performance route, hardware and project confirmation items. It is for design coordination; fabrication follows the approved shop drawing.

03 / Windows

Window systems

Thermal-break, non-thermal-break, sliding, crank and louver families. The table repeats the published catalogue values so a project team can compare like with like.

SeriesOpeningFrame / build-upPerformance routePublished built sizeHardware / note
H98SInward tilt-and-turn98 mm; thermal break 30 mm; glass 30 / 39 mmUw 1.8; 6 / 4 / 7 / acoustic 3450-900 x 600-2400 mm; 110 kgROTO hidden; Hoppe
FZ75Inward tilt-and-turn; integrated screen option75 mm; thermal break 34 mm; glass 28 / 39 mmUw 1.8; 6 / 4 / 7 / acoustic 3450-900 x 600-2400 mm; 110 kgHidden hardware
YKC65AFixed / casement / top-hung / tilt-and-turn70 mm; wall 2.0-2.5 mm; break 28 mm; glass 26 mmUw 2.0; 7 / 4 / 7 / acoustic 3600-900 x 600-1800 mmKinlong
YKS150ASliding window150 mm; thermal break; 2.0 mmProject dependent; NFRC / CSA route600-1500 x 1000-2000 mm; 80 kgVBH
YSV100ALouver window100 mm; non-thermal-break; 2.0 mmProject dependent; Intertek tested / ENERGY STAR accredited600-1500 x 600-2400 mm; 80 kgKinlong handles and crank

04 / Doors

Door and large-opening systems

Door selection is driven by width, leaf weight, track condition, drainage and how the opening is used. Do not select by frame depth alone.

SeriesOpeningFrame / build-upPerformance routePublished built sizeHardware / note
F130TLift-and-slide door130 mm; thermal break 18 / 18 mmUw 1.8-2.0; 6 / 4 / 7 / acoustic 3720-2000 x 1800-2700 mm; 120 / 300 kgCMECH; mesh screen door
F150TSLift-and-slide door150 mm; thermal break 28 / 28 mm; glass 30 / 39 mmUw 1.7-1.8; 6 / 4 / 7 / acoustic 3720-2500 x 1800-3200 mm; 300 / 500 kgCMECH; SUS304 track
D70Bifold70 mm; wall 2.0-2.5 mm; break 28 mm; glass 26 mmUw 2.0; 7 / 4 / 7 / acoustic 3Leaf 700-800 x 2200-3200 mmKesenberg; leaf load to confirm
YKS150ALift-and-slide door150 mm; thermal break; 2.0 mmProject dependent; NFRC / CSA / NAFS / AS2047 route600-3000 x 1000-3500 mm; 100 kgVBH
YKF80AFolding door80 mm; thermal break; 2.0 mmProject dependent; NFRC / CSA / NAFS route600-1000 x 1000-3500 mm; 100 kgKerssenberg

05 / Facade + outdoor

Facade bays and outdoor living

These systems are project assemblies. The opening schedule, drainage, fixing, wind exposure and local installation boundary need to be reviewed together.

MQ65

Stick facade

Mullion 65 x 192 mm; transom 65 x 128 mm; wall 3.0-3.5 mm; break 24 mm; glass 33 mm. Span at most 1500 mm. Glass follows the insert and is glazed on site.

YSP147

Louver pergola

147 type aluminium louver pergola in 6063 aluminium. Published modules include 2.5 x 3, 3 x 3, 3 x 3.6, 3 x 4, 4 x 4 and 3 x 6 m. Manual or electric drive.

06 / Performance route

What the numbers mean

A system value is only meaningful with its glass, size, hardware, seals, installation and destination standard. The status column prevents a catalogue number from becoming an unqualified promise.

ItemWhat it describesCatalogue statusProject input
UwWhole-window thermal transmittance, including the selected glazing and spacer.Published where shown; otherwise project dependent.Glass make-up, size, spacer, frame and destination climate.
A / W / WAir leakage, water tightness and wind resistance route.Band shown in the catalogue row; test route to confirm.Exposure, height, pressure, drainage, seals and fixing.
AcousticSound reduction of the complete opening, not the frame alone.Acoustic band shown only where stated.Glass build-up, seals, vents, junctions and target room.
NFRC / CSA / NAFS / AS2047 / CEThe standard or certification route used for the destination market.Route listed where available; certificate package is project issue.Country, authority, product configuration and approved drawing.
CorrosionHardware, coating and drainage choice for the exposure class.Salt-spray grade is selected in the quotation.Coast distance, salt exposure, finish, maintenance and hardware.

07 / Project checks

What must be confirmed before order

01

Geometry

Final opening width, height, quantity, corner condition, sill and fixing line.

02

Glass

Make-up, thickness, safety, Low-E, spacer, acoustic target and local sourcing.

03

Exposure

Wind, water, salt spray, drainage, shading and maintenance access.

04

Scope

Factory drawings, packing, freight, local permits, foundations, installation and commissioning.

08 / Next document

Send the drawing and let the row become a project specification.

Include the series, dimensions, quantity, destination, glass direction, finish and any site photograph. We will return the system route, open questions and quotation basis.